The Straight Spike (Bond-Tube ID) (CV-012) offers a reliable single-use connection, stable dimensions and smooth sealing surfaces, molded from ABS for IV sets, drip flow control and bag or bottle access. ' . bfaq_company_name() . ' supplies it with consistent lot-to-lot quality and OEM/ODM options.
Definition
A straight spike (bond-tube id) is one of the small standardized parts that make a medical fluid path work. Its job is to connect, seal or control flow between two segments of a line, and it is manufactured from device-qualified plastics for reliable single-use performance.
What separates a medical-grade part from a generic fitting is repeatability. Sealing surfaces are smooth and consistent, dimensions hold across the lot, and the resin is selected for fluid compatibility and sterilization.
It helps to picture where the part sits. A finished single-use device — an IV set, a transfer line, a dialysis circuit — is an assembly of molded plastic pieces joined into one fluid path. Each piece has a narrow job, and the value of standardization is that pieces from a catalog snap together predictably, so an assembler can design around known interfaces instead of bespoke fittings.
About This Component
The Straight Spike (Bond-Tube ID) is supplied as a single-use molded part for IV sets, drip flow control and bag or bottle access. Its interface follows standard conventions so it mates predictably with compatible components, and it is produced in ABS by default, with other medical-grade resins available on request.
Like all Baixin Bio components, it can be customized for material, color, dimensions, packaging and assembly. For a precise specification — exact dimensions, tolerances, sterilization validation, packaging counts and minimum order quantity — request a drawing and samples through the inquiry form.
Key Advantages
For device assemblers specifying straight spike (bond-tube id), the benefits that matter most are reliability and repeatability:
- Available in multiple materials and colors
- Supports OEM and ODM customization of dimensions and packaging
- High-volume manufacturing with stable quality
- Compatibility with common sterilization methods
- Standardized interface that interoperates with compliant luer components
- Leak-resistant seal that holds under normal line pressure
Taken together, these are the reasons device makers standardize on molded medical components rather than improvising connections: the part is predictable, documented and available at volume, which keeps the finished device safe and the production line moving.
Common Applications
Typical applications for straight spike (bond-tube id) span the disposable device landscape:
- Hemodialysis circuits
- Enteral feeding sets
- Laboratory fluid handling
- Irrigation sets
- Disposable diagnostic devices
What links these applications is risk. Each one moves fluid into or out of a patient or a sample, so a leak, a wrong connection or a contaminated surface has consequences. Standardized single-use components reduce that risk by making every junction predictable and by being discarded rather than reprocessed, which is the safer default for most modern disposable devices.
How to Specify and Choose
When you select a component, work through these variables before requesting a quote:
- Packaging format and order volume for the program
- The connection standard the mating part uses (luer slip, luer lock or a specific ISO 80369 series)
- The working pressure the junction must hold without leaking or separating
- The fluid and its chemical compatibility with the candidate resin
- The inner and outer diameters of the tubing the part bonds to
With those answers in hand, a supplier can confirm a standard part or scope a custom one without back-and-forth. Sharing a drawing or a physical sample removes the remaining ambiguity.
Industry Standards
The relevant standards work is centered on ISO 80369, the small-bore connector series designed to prevent dangerous misconnections across IV, enteral, respiratory and other applications. Alongside connection standards, material biocompatibility and a validated sterilization method (EO, gamma or autoclave) define whether a component is fit for medical use.
For ABS components, the practical sterilization options are EO and gamma; the choice is confirmed against the finished device and its validated process.
Much of the modern standards work exists to prevent misconnection. Historically a single luer taper served many applications, which made cross-connections physically possible; the ISO 80369 series assign distinct geometries to different uses so incompatible lines simply will not mate. When you specify a connector, identifying the correct series for the application is therefore a safety decision, not just a fit decision.
This page is informational and does not replace device-specific regulatory or validation guidance. Confirm exact standards, biocompatibility and sterilization requirements for your product with your quality team and your supplier.
Frequently Asked Questions
What materials are used?
Depending on the part, medical-grade PC, PP, PVC, ABS, PE or POM is used, selected for the connection method, fluid path and sterilization requirement.
How is it sterilized?
Components are compatible with validated single-use sterilization such as ethylene oxide, gamma irradiation or steam autoclave, depending on the resin. Confirm the method for your device.
Is it compatible with ISO 80369?
Luer interfaces follow small-bore connector conventions. Confirm exact ISO 80369 series compatibility for your application with Baixin Bio before specifying.
What order volumes are supported?
Baixin Bio supplies disposable device assemblers in production volumes, with consistent lot-to-lot quality and export-friendly communication.
Can I request samples?
Yes. Samples and drawings are welcome and recommended before committing to volume. Use the inquiry form to request them.
Related Products
Related Questions
Explore More
Need Medical Connectors or Components?
Baixin Bio manufactures luer connectors, valves, drip chambers, clamps, caps and tubing, with OEM and ODM customization. Send your drawings or samples for a quote.
Request a Quote