The Female Luer Straight Connector (JT-016) is molded from polycarbonate, chosen for the part's connection and fluid-path requirements. The material supports the sterilization and compatibility needs of IV infusion sets and fluid-transfer lines. Custom material and color are available from ' . bfaq_company_name() . '.
Definition
At its core, a female luer straight connector is a molded plastic component that creates or controls a connection in a medical fluid line. It is engineered so that tubing, syringes, devices and accessories join with a predictable, leak-resistant fit, and it is produced as a single-use part from medical-grade thermoplastics.
The component is small, but it carries real responsibility: a poor seal or an out-of-tolerance dimension can compromise an entire single-use assembly, which is why medical molders control material, tooling and process tightly.
Seen in context, the component is one link in a chain. A complete single-use set joins several molded parts into one continuous fluid path, and each junction has to seal and hold. Because the interfaces are standardized, an assembler can combine catalog parts with confidence rather than designing every joint from scratch.
About This Component
The Female Luer Straight Connector is supplied as a single-use molded part for IV infusion sets and fluid-transfer lines. Its interface follows standard conventions so it mates predictably with compatible components, and it is produced in polycarbonate by default, with other medical-grade resins available on request.
Like all Baixin Bio components, it can be customized for material, color, dimensions, packaging and assembly. For a precise specification — exact dimensions, tolerances, sterilization validation, packaging counts and minimum order quantity — request a drawing and samples through the inquiry form.
Key Advantages
Where female luer straight connector earns its place, it is for a handful of practical reasons:
- Single-use design that supports sterile, disposable workflows
- Medical-grade resin selected for fluid compatibility
- Dimensional consistency across production lots
- Smooth fluid-contact surfaces for reliable connection
- Available in multiple materials and colors
- Supports OEM and ODM customization of dimensions and packaging
None of these advantages matter in isolation; their value is cumulative. A part that seals well but drifts dimensionally, or one that is consistent but slow to supply, fails the assembler. The point is to get all of them at once, reliably, lot after lot.
Common Applications
The settings that rely on female luer straight connector include:
- Laboratory fluid handling
- Irrigation sets
- Disposable diagnostic devices
- Syringe and pump connections
- IV infusion sets
Across all of these uses, the underlying requirement is the same: a connection that is secure, leak-resistant and safe to make once and discard. That is why standardized, single-use molded components dominate the category — they remove variability from the most failure-prone part of a fluid path, the junction, and they let a device be assembled quickly and qualified as a unit.
How to Specify and Choose
Specifying the right part is mostly about matching a handful of variables to your assembly:
- The working pressure the junction must hold without leaking or separating
- The fluid and its chemical compatibility with the candidate resin
- The inner and outer diameters of the tubing the part bonds to
- The sterilization method the finished device will undergo
- Whether the part is single-use or intended for limited reuse
Once these are defined, sample qualification against your own process is the last step before volume. If no catalog part matches, these same inputs drive a custom mold.
Industry Standards
The relevant standards work is centered on ISO 80369, the small-bore connector series designed to prevent dangerous misconnections across IV, enteral, respiratory and other applications. Alongside connection standards, material biocompatibility and a validated sterilization method (EO, gamma or autoclave) define whether a component is fit for medical use.
For polycarbonate components, the practical sterilization options are gamma and ethylene oxide (EO); the choice is confirmed against the finished device and its validated process.
The reason the standards landscape moved toward ISO 80369 is patient safety: when every line used the same luer taper, it was physically possible to connect, say, an enteral line to an intravenous one. The newer series give different applications deliberately incompatible geometries so a dangerous misconnection cannot be made by accident. For a component maker, that means confirming which series an application requires before specifying a part.
This page is informational and does not replace device-specific regulatory or validation guidance. Confirm exact standards, biocompatibility and sterilization requirements for your product with your quality team and your supplier.
Frequently Asked Questions
What materials are used?
Depending on the part, medical-grade PC, PP, PVC, ABS, PE or POM is used, selected for the connection method, fluid path and sterilization requirement.
How is it sterilized?
Components are compatible with validated single-use sterilization such as ethylene oxide, gamma irradiation or steam autoclave, depending on the resin. Confirm the method for your device.
Is it compatible with ISO 80369?
Luer interfaces follow small-bore connector conventions. Confirm exact ISO 80369 series compatibility for your application with Baixin Bio before specifying.
What order volumes are supported?
Baixin Bio supplies disposable device assemblers in production volumes, with consistent lot-to-lot quality and export-friendly communication.
Can I request samples?
Yes. Samples and drawings are welcome and recommended before committing to volume. Use the inquiry form to request them.
Related Products
Related Questions
Explore More
Need Medical Connectors or Components?
Baixin Bio manufactures luer connectors, valves, drip chambers, clamps, caps and tubing, with OEM and ODM customization. Send your drawings or samples for a quote.