The Drip Chamber with Spike (Large Bore) (CV-004) is offered for common tubing sizes used in IV sets, drip flow control and bag or bottle access; exact inner/outer diameters can be specified. It is molded from medical PVC. Baixin Bio customizes dimensions on request.
Definition
At its core, a drip chamber with spike (large bore) is a molded plastic component that creates or controls a connection in a medical fluid line. It is engineered so that tubing, syringes, devices and accessories join with a predictable, leak-resistant fit, and it is produced as a single-use part from medical-grade thermoplastics.
The component is small, but it carries real responsibility: a poor seal or an out-of-tolerance dimension can compromise an entire single-use assembly, which is why medical molders control material, tooling and process tightly.
Seen in context, the component is one link in a chain. A complete single-use set joins several molded parts into one continuous fluid path, and each junction has to seal and hold. Because the interfaces are standardized, an assembler can combine catalog parts with confidence rather than designing every joint from scratch.
About This Component
The Drip Chamber with Spike (Large Bore) is supplied as a single-use molded part for IV sets, drip flow control and bag or bottle access. Its interface follows standard conventions so it mates predictably with compatible components, and it is produced in medical PVC by default, with other medical-grade resins available on request.
Like all Baixin Bio components, it can be customized for material, color, dimensions, packaging and assembly. For a precise specification — exact dimensions, tolerances, sterilization validation, packaging counts and minimum order quantity — request a drawing and samples through the inquiry form.
Key Advantages
The practical advantages of drip chamber with spike (large bore) cluster around safety, consistency and supply:
- Compatibility with common sterilization methods
- Standardized interface that interoperates with compliant luer components
- Leak-resistant seal that holds under normal line pressure
- Single-use design that supports sterile, disposable workflows
- Medical-grade resin selected for fluid compatibility
- Dimensional consistency across production lots
None of these advantages matter in isolation; their value is cumulative. A part that seals well but drifts dimensionally, or one that is consistent but slow to supply, fails the assembler. The point is to get all of them at once, reliably, lot after lot.
Common Applications
You will find drip chamber with spike (large bore) across a range of single-use fluid-handling assemblies, including:
- Irrigation sets
- Disposable diagnostic devices
- Syringe and pump connections
- IV infusion sets
- Blood and fluid transfer lines
What links these applications is risk. Each one moves fluid into or out of a patient or a sample, so a leak, a wrong connection or a contaminated surface has consequences. Standardized single-use components reduce that risk by making every junction predictable and by being discarded rather than reprocessed, which is the safer default for most modern disposable devices.
How to Specify and Choose
When you select a component, work through these variables before requesting a quote:
- The connection standard the mating part uses (luer slip, luer lock or a specific ISO 80369 series)
- The working pressure the junction must hold without leaking or separating
- The fluid and its chemical compatibility with the candidate resin
- The inner and outer diameters of the tubing the part bonds to
- The sterilization method the finished device will undergo
Once these are defined, sample qualification against your own process is the last step before volume. If no catalog part matches, these same inputs drive a custom mold.
Industry Standards
From a compliance standpoint, the component sits at the intersection of connector standards and material standards. The ISO 80369 family governs small-bore connection geometry to prevent misconnection, while biocompatibility documentation and a validated sterilization route — EO, gamma or autoclave — establish that the molded material is acceptable for its intended contact.
For medical PVC components, the practical sterilization options are EO and gamma; the choice is confirmed against the finished device and its validated process.
Much of the modern standards work exists to prevent misconnection. Historically a single luer taper served many applications, which made cross-connections physically possible; the ISO 80369 series assign distinct geometries to different uses so incompatible lines simply will not mate. When you specify a connector, identifying the correct series for the application is therefore a safety decision, not just a fit decision.
This page is informational and does not replace device-specific regulatory or validation guidance. Confirm exact standards, biocompatibility and sterilization requirements for your product with your quality team and your supplier.
Frequently Asked Questions
What order volumes are supported?
Baixin Bio supplies disposable device assemblers in production volumes, with consistent lot-to-lot quality and export-friendly communication.
Can I request samples?
Yes. Samples and drawings are welcome and recommended before committing to volume. Use the inquiry form to request them.
Is drip chamber with spike (large bore) available for OEM or ODM projects?
Yes. Baixin Bio manufactures to drawings and samples, customizing material, color, dimensions, packaging and assembly. Send your specification for a quote.
What materials are used?
Depending on the part, medical-grade PC, PP, PVC, ABS, PE or POM is used, selected for the connection method, fluid path and sterilization requirement.
How is it sterilized?
Components are compatible with validated single-use sterilization such as ethylene oxide, gamma irradiation or steam autoclave, depending on the resin. Confirm the method for your device.
Related Products
Related Questions
Explore More
Need Medical Connectors or Components?
Baixin Bio manufactures luer connectors, valves, drip chambers, clamps, caps and tubing, with OEM and ODM customization. Send your drawings or samples for a quote.