The Sliding Rotating Male Connector (JT-010) is offered for common tubing sizes used in IV infusion sets and fluid-transfer lines; exact inner/outer diameters can be specified. It is molded from polycarbonate. ' . bfaq_company_name() . ' customizes dimensions on request.
Definition
The term sliding rotating male connector refers to a precision component within IV infusion sets and fluid-transfer lines. It defines how a fluid line connects, branches, seals or regulates, and it is molded to tight tolerances so the interface performs the same way across an entire production lot.
What separates a medical-grade part from a generic fitting is repeatability. Sealing surfaces are smooth and consistent, dimensions hold across the lot, and the resin is selected for fluid compatibility and sterilization.
Seen in context, the component is one link in a chain. A complete single-use set joins several molded parts into one continuous fluid path, and each junction has to seal and hold. Because the interfaces are standardized, an assembler can combine catalog parts with confidence rather than designing every joint from scratch.
About This Component
The Sliding Rotating Male Connector is supplied as a single-use molded part for IV infusion sets and fluid-transfer lines. Its interface follows standard conventions so it mates predictably with compatible components, and it is produced in polycarbonate by default, with other medical-grade resins available on request.
Like all Baixin Bio components, it can be customized for material, color, dimensions, packaging and assembly. For a precise specification — exact dimensions, tolerances, sterilization validation, packaging counts and minimum order quantity — request a drawing and samples through the inquiry form.
Key Advantages
The reasons sliding rotating male connector is specified come down to a few concrete advantages:
- Dimensional consistency across production lots
- Smooth fluid-contact surfaces for reliable connection
- Available in multiple materials and colors
- Supports OEM and ODM customization of dimensions and packaging
- High-volume manufacturing with stable quality
- Compatibility with common sterilization methods
None of these advantages matter in isolation; their value is cumulative. A part that seals well but drifts dimensionally, or one that is consistent but slow to supply, fails the assembler. The point is to get all of them at once, reliably, lot after lot.
Common Applications
In practice, sliding rotating male connector appears wherever a controlled fluid connection is needed:
- Laboratory fluid handling
- Irrigation sets
- Disposable diagnostic devices
- Syringe and pump connections
- IV infusion sets
The common thread is that every one of these settings needs junctions it can trust. A standardized, single-use component delivers that trust at scale: the same interface, the same seal and the same material behavior across an entire production lot, so the clinical team and the device maker are not relying on a one-off fitting at a critical point in the line.
How to Specify and Choose
Specifying the right part is mostly about matching a handful of variables to your assembly:
- The working pressure the junction must hold without leaking or separating
- The fluid and its chemical compatibility with the candidate resin
- The inner and outer diameters of the tubing the part bonds to
- The sterilization method the finished device will undergo
- Whether the part is single-use or intended for limited reuse
Once these are defined, sample qualification against your own process is the last step before volume. If no catalog part matches, these same inputs drive a custom mold.
Industry Standards
From a compliance standpoint, the component sits at the intersection of connector standards and material standards. The ISO 80369 family governs small-bore connection geometry to prevent misconnection, while biocompatibility documentation and a validated sterilization route — EO, gamma or autoclave — establish that the molded material is acceptable for its intended contact.
For polycarbonate components, the practical sterilization options are gamma and ethylene oxide (EO); the choice is confirmed against the finished device and its validated process.
Much of the modern standards work exists to prevent misconnection. Historically a single luer taper served many applications, which made cross-connections physically possible; the ISO 80369 series assign distinct geometries to different uses so incompatible lines simply will not mate. When you specify a connector, identifying the correct series for the application is therefore a safety decision, not just a fit decision.
This page is informational and does not replace device-specific regulatory or validation guidance. Confirm exact standards, biocompatibility and sterilization requirements for your product with your quality team and your supplier.
Frequently Asked Questions
Is it compatible with ISO 80369?
Luer interfaces follow small-bore connector conventions. Confirm exact ISO 80369 series compatibility for your application with Baixin Bio before specifying.
What order volumes are supported?
Baixin Bio supplies disposable device assemblers in production volumes, with consistent lot-to-lot quality and export-friendly communication.
Can I request samples?
Yes. Samples and drawings are welcome and recommended before committing to volume. Use the inquiry form to request them.
Is sliding rotating male connector available for OEM or ODM projects?
Yes. Baixin Bio manufactures to drawings and samples, customizing material, color, dimensions, packaging and assembly. Send your specification for a quote.
Related Products
Related Questions
Explore More
Need Medical Connectors or Components?
Baixin Bio manufactures luer connectors, valves, drip chambers, clamps, caps and tubing, with OEM and ODM customization. Send your drawings or samples for a quote.