Skip to content

What applications is In-Line Filter (Dual Bond-Tube) suitable for?

Quick Answer

The In-Line Filter (Dual Bond-Tube) (CV-019) suits IV sets, drip flow control and bag or bottle access and similar single-use fluid-handling assemblies. It is molded from polycarbonate for dependable connections. ' . bfaq_company_name() . ' offers it as a standard or customized part.

Definition

An in-line filter (dual bond-tube) is one of the small standardized parts that make a medical fluid path work. Its job is to connect, seal or control flow between two segments of a line, and it is manufactured from device-qualified plastics for reliable single-use performance.

Because the part sits directly in the fluid path, three things matter most: a dependable seal, dimensional consistency from part to part, and a material that is compatible with the fluid and the chosen sterilization method.

It helps to picture where the part sits. A finished single-use device — an IV set, a transfer line, a dialysis circuit — is an assembly of molded plastic pieces joined into one fluid path. Each piece has a narrow job, and the value of standardization is that pieces from a catalog snap together predictably, so an assembler can design around known interfaces instead of bespoke fittings.

About This Component

The In-Line Filter (Dual Bond-Tube) is supplied as a single-use molded part for IV sets, drip flow control and bag or bottle access. Its interface follows standard conventions so it mates predictably with compatible components, and it is produced in polycarbonate by default, with other medical-grade resins available on request.

Like all Baixin Bio components, it can be customized for material, color, dimensions, packaging and assembly. For a precise specification — exact dimensions, tolerances, sterilization validation, packaging counts and minimum order quantity — request a drawing and samples through the inquiry form.

Key Advantages

For device assemblers specifying in-line filter (dual bond-tube), the benefits that matter most are reliability and repeatability:

  • Supports OEM and ODM customization of dimensions and packaging
  • High-volume manufacturing with stable quality
  • Compatibility with common sterilization methods
  • Standardized interface that interoperates with compliant luer components
  • Leak-resistant seal that holds under normal line pressure

None of these advantages matter in isolation; their value is cumulative. A part that seals well but drifts dimensionally, or one that is consistent but slow to supply, fails the assembler. The point is to get all of them at once, reliably, lot after lot.

Common Applications

Typical applications for in-line filter (dual bond-tube) span the disposable device landscape:

  • Irrigation sets
  • Disposable diagnostic devices
  • Syringe and pump connections
  • IV infusion sets

Across all of these uses, the underlying requirement is the same: a connection that is secure, leak-resistant and safe to make once and discard. That is why standardized, single-use molded components dominate the category — they remove variability from the most failure-prone part of a fluid path, the junction, and they let a device be assembled quickly and qualified as a unit.

How to Specify and Choose

Specifying the right part is mostly about matching a handful of variables to your assembly:

  • The connection standard the mating part uses (luer slip, luer lock or a specific ISO 80369 series)
  • The working pressure the junction must hold without leaking or separating
  • The fluid and its chemical compatibility with the candidate resin
  • The inner and outer diameters of the tubing the part bonds to
  • The sterilization method the finished device will undergo

Getting these settled early means the first samples are usable and the program moves to volume faster. When a standard part does not fit, the same variables become the brief for an OEM or ODM tooling project.

Industry Standards

Two standards questions dominate this category: connection geometry and sterilization. Connection geometry is increasingly defined by the ISO 80369 series, which separates applications so incompatible lines cannot mate; sterilization is handled by validated EO, gamma or steam autoclave processes matched to the resin and the device.

For polycarbonate components, the practical sterilization options are gamma and ethylene oxide (EO); the choice is confirmed against the finished device and its validated process.

Much of the modern standards work exists to prevent misconnection. Historically a single luer taper served many applications, which made cross-connections physically possible; the ISO 80369 series assign distinct geometries to different uses so incompatible lines simply will not mate. When you specify a connector, identifying the correct series for the application is therefore a safety decision, not just a fit decision.

This page is informational and does not replace device-specific regulatory or validation guidance. Confirm exact standards, biocompatibility and sterilization requirements for your product with your quality team and your supplier.

Frequently Asked Questions

Is in-line filter (dual bond-tube) available for OEM or ODM projects?

Yes. Baixin Bio manufactures to drawings and samples, customizing material, color, dimensions, packaging and assembly. Send your specification for a quote.

What materials are used?

Depending on the part, medical-grade PC, PP, PVC, ABS, PE or POM is used, selected for the connection method, fluid path and sterilization requirement.

How is it sterilized?

Components are compatible with validated single-use sterilization such as ethylene oxide, gamma irradiation or steam autoclave, depending on the resin. Confirm the method for your device.

Is it compatible with ISO 80369?

Luer interfaces follow small-bore connector conventions. Confirm exact ISO 80369 series compatibility for your application with Baixin Bio before specifying.

Explore More

Need Medical Connectors or Components?

Baixin Bio manufactures luer connectors, valves, drip chambers, clamps, caps and tubing, with OEM and ODM customization. Send your drawings or samples for a quote.

Request a Quote