The In-Line Filter (Dual Bond-Tube) (CV-019) is molded from polycarbonate, chosen for the part's connection and fluid-path requirements. The material supports the sterilization and compatibility needs of IV sets, drip flow control and bag or bottle access. Custom material and color are available from ' . bfaq_company_name() . '.
Definition
At its core, an in-line filter (dual bond-tube) is a molded plastic component that creates or controls a connection in a medical fluid line. It is engineered so that tubing, syringes, devices and accessories join with a predictable, leak-resistant fit, and it is produced as a single-use part from medical-grade thermoplastics.
What separates a medical-grade part from a generic fitting is repeatability. Sealing surfaces are smooth and consistent, dimensions hold across the lot, and the resin is selected for fluid compatibility and sterilization.
Seen in context, the component is one link in a chain. A complete single-use set joins several molded parts into one continuous fluid path, and each junction has to seal and hold. Because the interfaces are standardized, an assembler can combine catalog parts with confidence rather than designing every joint from scratch.
About This Component
The In-Line Filter (Dual Bond-Tube) is supplied as a single-use molded part for IV sets, drip flow control and bag or bottle access. Its interface follows standard conventions so it mates predictably with compatible components, and it is produced in polycarbonate by default, with other medical-grade resins available on request.
Like all Baixin Bio components, it can be customized for material, color, dimensions, packaging and assembly. For a precise specification — exact dimensions, tolerances, sterilization validation, packaging counts and minimum order quantity — request a drawing and samples through the inquiry form.
Key Advantages
For device assemblers specifying in-line filter (dual bond-tube), the benefits that matter most are reliability and repeatability:
- Medical-grade resin selected for fluid compatibility
- Dimensional consistency across production lots
- Smooth fluid-contact surfaces for reliable connection
- Available in multiple materials and colors
- Supports OEM and ODM customization of dimensions and packaging
- High-volume manufacturing with stable quality
In short, the component earns its place by being unremarkable in the best way: it fits, it seals, it is available, and it behaves the same every time, so engineering attention can go to the device rather than the fitting.
Common Applications
Typical applications for in-line filter (dual bond-tube) span the disposable device landscape:
- Blood and fluid transfer lines
- Hemodialysis circuits
- Enteral feeding sets
- Laboratory fluid handling
- Irrigation sets
The common thread is that every one of these settings needs junctions it can trust. A standardized, single-use component delivers that trust at scale: the same interface, the same seal and the same material behavior across an entire production lot, so the clinical team and the device maker are not relying on a one-off fitting at a critical point in the line.
How to Specify and Choose
Specifying the right part is mostly about matching a handful of variables to your assembly:
- The sterilization method the finished device will undergo
- Whether the part is single-use or intended for limited reuse
- Color coding or opacity requirements for the assembly
- Packaging format and order volume for the program
- The connection standard the mating part uses (luer slip, luer lock or a specific ISO 80369 series)
With those answers in hand, a supplier can confirm a standard part or scope a custom one without back-and-forth. Sharing a drawing or a physical sample removes the remaining ambiguity.
Industry Standards
The relevant standards work is centered on ISO 80369, the small-bore connector series designed to prevent dangerous misconnections across IV, enteral, respiratory and other applications. Alongside connection standards, material biocompatibility and a validated sterilization method (EO, gamma or autoclave) define whether a component is fit for medical use.
For polycarbonate components, the practical sterilization options are gamma and ethylene oxide (EO); the choice is confirmed against the finished device and its validated process.
Much of the modern standards work exists to prevent misconnection. Historically a single luer taper served many applications, which made cross-connections physically possible; the ISO 80369 series assign distinct geometries to different uses so incompatible lines simply will not mate. When you specify a connector, identifying the correct series for the application is therefore a safety decision, not just a fit decision.
This page is informational and does not replace device-specific regulatory or validation guidance. Confirm exact standards, biocompatibility and sterilization requirements for your product with your quality team and your supplier.
Frequently Asked Questions
Is in-line filter (dual bond-tube) available for OEM or ODM projects?
Yes. Baixin Bio manufactures to drawings and samples, customizing material, color, dimensions, packaging and assembly. Send your specification for a quote.
What materials are used?
Depending on the part, medical-grade PC, PP, PVC, ABS, PE or POM is used, selected for the connection method, fluid path and sterilization requirement.
How is it sterilized?
Components are compatible with validated single-use sterilization such as ethylene oxide, gamma irradiation or steam autoclave, depending on the resin. Confirm the method for your device.
Is it compatible with ISO 80369?
Luer interfaces follow small-bore connector conventions. Confirm exact ISO 80369 series compatibility for your application with Baixin Bio before specifying.
What order volumes are supported?
Baixin Bio supplies disposable device assemblers in production volumes, with consistent lot-to-lot quality and export-friendly communication.
Can I request samples?
Yes. Samples and drawings are welcome and recommended before committing to volume. Use the inquiry form to request them.
Related Products
Related Questions
Explore More
Need Medical Connectors or Components?
Baixin Bio manufactures luer connectors, valves, drip chambers, clamps, caps and tubing, with OEM and ODM customization. Send your drawings or samples for a quote.
Request a Quote