What is Beveled Straight Spike used for?

Quick Answer

The Beveled Straight Spike (CV-017) is a medical plastic component used in IV sets, drip flow control and bag or bottle access. It provides a secure, single-use connection in the fluid path and is molded from ABS. Baixin Bio supplies it in standard form and with OEM/ODM customization.

Definition

The term beveled straight spike refers to a precision component within IV sets, drip flow control and bag or bottle access. It defines how a fluid line connects, branches, seals or regulates, and it is molded to tight tolerances so the interface performs the same way across an entire production lot.

The component is small, but it carries real responsibility: a poor seal or an out-of-tolerance dimension can compromise an entire single-use assembly, which is why medical molders control material, tooling and process tightly.

To put it in context: a disposable fluid-handling device is rarely one molding. It is a chain of small components — connectors, valves, chambers, clamps, caps and tubing — assembled into a single path. Standard interfaces are what let those components come from a catalog and still fit, which is the whole reason this category of part exists.

About This Component

The Beveled Straight Spike is supplied as a single-use molded part for IV sets, drip flow control and bag or bottle access. Its interface follows standard conventions so it mates predictably with compatible components, and it is produced in ABS by default, with other medical-grade resins available on request.

Like all Baixin Bio components, it can be customized for material, color, dimensions, packaging and assembly. For a precise specification — exact dimensions, tolerances, sterilization validation, packaging counts and minimum order quantity — request a drawing and samples through the inquiry form.

Key Advantages

The reasons beveled straight spike is specified come down to a few concrete advantages:

  • Compatibility with common sterilization methods
  • Standardized interface that interoperates with compliant luer components
  • Leak-resistant seal that holds under normal line pressure
  • Single-use design that supports sterile, disposable workflows
  • Medical-grade resin selected for fluid compatibility
  • Dimensional consistency across production lots

Taken together, these are the reasons device makers standardize on molded medical components rather than improvising connections: the part is predictable, documented and available at volume, which keeps the finished device safe and the production line moving.

Common Applications

In practice, beveled straight spike appears wherever a controlled fluid connection is needed:

  • Blood and fluid transfer lines
  • Hemodialysis circuits
  • Enteral feeding sets
  • Laboratory fluid handling
  • Irrigation sets

The common thread is that every one of these settings needs junctions it can trust. A standardized, single-use component delivers that trust at scale: the same interface, the same seal and the same material behavior across an entire production lot, so the clinical team and the device maker are not relying on a one-off fitting at a critical point in the line.

How to Specify and Choose

When you select a component, work through these variables before requesting a quote:

  • The sterilization method the finished device will undergo
  • Whether the part is single-use or intended for limited reuse
  • Color coding or opacity requirements for the assembly
  • Packaging format and order volume for the program
  • The connection standard the mating part uses (luer slip, luer lock or a specific ISO 80369 series)

Once these are defined, sample qualification against your own process is the last step before volume. If no catalog part matches, these same inputs drive a custom mold.

Industry Standards

From a compliance standpoint, the component sits at the intersection of connector standards and material standards. The ISO 80369 family governs small-bore connection geometry to prevent misconnection, while biocompatibility documentation and a validated sterilization route — EO, gamma or autoclave — establish that the molded material is acceptable for its intended contact.

For ABS components, the practical sterilization options are EO and gamma; the choice is confirmed against the finished device and its validated process.

The reason the standards landscape moved toward ISO 80369 is patient safety: when every line used the same luer taper, it was physically possible to connect, say, an enteral line to an intravenous one. The newer series give different applications deliberately incompatible geometries so a dangerous misconnection cannot be made by accident. For a component maker, that means confirming which series an application requires before specifying a part.

This page is informational and does not replace device-specific regulatory or validation guidance. Confirm exact standards, biocompatibility and sterilization requirements for your product with your quality team and your supplier.

Frequently Asked Questions

How is it sterilized?

Components are compatible with validated single-use sterilization such as ethylene oxide, gamma irradiation or steam autoclave, depending on the resin. Confirm the method for your device.

Is it compatible with ISO 80369?

Luer interfaces follow small-bore connector conventions. Confirm exact ISO 80369 series compatibility for your application with Baixin Bio before specifying.

What order volumes are supported?

Baixin Bio supplies disposable device assemblers in production volumes, with consistent lot-to-lot quality and export-friendly communication.

Can I request samples?

Yes. Samples and drawings are welcome and recommended before committing to volume. Use the inquiry form to request them.

Is beveled straight spike available for OEM or ODM projects?

Yes. Baixin Bio manufactures to drawings and samples, customizing material, color, dimensions, packaging and assembly. Send your specification for a quote.

What materials are used?

Depending on the part, medical-grade PC, PP, PVC, ABS, PE or POM is used, selected for the connection method, fluid path and sterilization requirement.