The 2-Way Stopcock (Dual Luer) (CV-032) is a medical plastic component used in IV sets, drip flow control and bag or bottle access. It provides a secure, single-use connection in the fluid path and is molded from polycarbonate. Baixin Bio supplies it in standard form and with OEM/ODM customization.
Definition
The term 2-way stopcock (dual luer) refers to a precision component within IV sets, drip flow control and bag or bottle access. It defines how a fluid line connects, branches, seals or regulates, and it is molded to tight tolerances so the interface performs the same way across an entire production lot.
What separates a medical-grade part from a generic fitting is repeatability. Sealing surfaces are smooth and consistent, dimensions hold across the lot, and the resin is selected for fluid compatibility and sterilization.
It helps to picture where the part sits. A finished single-use device — an IV set, a transfer line, a dialysis circuit — is an assembly of molded plastic pieces joined into one fluid path. Each piece has a narrow job, and the value of standardization is that pieces from a catalog snap together predictably, so an assembler can design around known interfaces instead of bespoke fittings.
About This Component
The 2-Way Stopcock (Dual Luer) is supplied as a single-use molded part for IV sets, drip flow control and bag or bottle access. Its interface follows standard conventions so it mates predictably with compatible components, and it is produced in polycarbonate by default, with other medical-grade resins available on request.
Like all Baixin Bio components, it can be customized for material, color, dimensions, packaging and assembly. For a precise specification — exact dimensions, tolerances, sterilization validation, packaging counts and minimum order quantity — request a drawing and samples through the inquiry form.
Key Advantages
Where 2-way stopcock (dual luer) earns its place, it is for a handful of practical reasons:
- Compatibility with common sterilization methods
- Standardized interface that interoperates with compliant luer components
- Leak-resistant seal that holds under normal line pressure
- Single-use design that supports sterile, disposable workflows
- Medical-grade resin selected for fluid compatibility
- Dimensional consistency across production lots
Taken together, these are the reasons device makers standardize on molded medical components rather than improvising connections: the part is predictable, documented and available at volume, which keeps the finished device safe and the production line moving.
Common Applications
The settings that rely on 2-way stopcock (dual luer) include:
- Syringe and pump connections
- IV infusion sets
- Blood and fluid transfer lines
- Hemodialysis circuits
- Enteral feeding sets
What links these applications is risk. Each one moves fluid into or out of a patient or a sample, so a leak, a wrong connection or a contaminated surface has consequences. Standardized single-use components reduce that risk by making every junction predictable and by being discarded rather than reprocessed, which is the safer default for most modern disposable devices.
How to Specify and Choose
A good specification answers a short list of questions up front:
- The fluid and its chemical compatibility with the candidate resin
- The inner and outer diameters of the tubing the part bonds to
- The sterilization method the finished device will undergo
- Whether the part is single-use or intended for limited reuse
- Color coding or opacity requirements for the assembly
With those answers in hand, a supplier can confirm a standard part or scope a custom one without back-and-forth. Sharing a drawing or a physical sample removes the remaining ambiguity.
Industry Standards
From a compliance standpoint, the component sits at the intersection of connector standards and material standards. The ISO 80369 family governs small-bore connection geometry to prevent misconnection, while biocompatibility documentation and a validated sterilization route — EO, gamma or autoclave — establish that the molded material is acceptable for its intended contact.
For polycarbonate components, the practical sterilization options are gamma and ethylene oxide (EO); the choice is confirmed against the finished device and its validated process.
Much of the modern standards work exists to prevent misconnection. Historically a single luer taper served many applications, which made cross-connections physically possible; the ISO 80369 series assign distinct geometries to different uses so incompatible lines simply will not mate. When you specify a connector, identifying the correct series for the application is therefore a safety decision, not just a fit decision.
This page is informational and does not replace device-specific regulatory or validation guidance. Confirm exact standards, biocompatibility and sterilization requirements for your product with your quality team and your supplier.
Frequently Asked Questions
How is it sterilized?
Components are compatible with validated single-use sterilization such as ethylene oxide, gamma irradiation or steam autoclave, depending on the resin. Confirm the method for your device.
Is it compatible with ISO 80369?
Luer interfaces follow small-bore connector conventions. Confirm exact ISO 80369 series compatibility for your application with Baixin Bio before specifying.
What order volumes are supported?
Baixin Bio supplies disposable device assemblers in production volumes, with consistent lot-to-lot quality and export-friendly communication.
Can I request samples?
Yes. Samples and drawings are welcome and recommended before committing to volume. Use the inquiry form to request them.
Is 2-way stopcock (dual luer) available for OEM or ODM projects?
Yes. Baixin Bio manufactures to drawings and samples, customizing material, color, dimensions, packaging and assembly. Send your specification for a quote.
What materials are used?
Depending on the part, medical-grade PC, PP, PVC, ABS, PE or POM is used, selected for the connection method, fluid path and sterilization requirement.
Related Products
Related Questions
Explore More
Need Medical Connectors or Components?
Baixin Bio manufactures luer connectors, valves, drip chambers, clamps, caps and tubing, with OEM and ODM customization. Send your drawings or samples for a quote.
Request a Quote