The Dual-Row Tube Clamp (Mixed Sizes) (TS-006) is a medical plastic component used in IV infusion sets and tubing flow control. It provides a secure, single-use connection in the fluid path and is molded from acetal (POM). Baixin Bio supplies it in standard form and with OEM/ODM customization.
Definition
The term dual-row tube clamp (mixed sizes) refers to a precision component within IV infusion sets and tubing flow control. It defines how a fluid line connects, branches, seals or regulates, and it is molded to tight tolerances so the interface performs the same way across an entire production lot.
What separates a medical-grade part from a generic fitting is repeatability. Sealing surfaces are smooth and consistent, dimensions hold across the lot, and the resin is selected for fluid compatibility and sterilization.
It helps to picture where the part sits. A finished single-use device — an IV set, a transfer line, a dialysis circuit — is an assembly of molded plastic pieces joined into one fluid path. Each piece has a narrow job, and the value of standardization is that pieces from a catalog snap together predictably, so an assembler can design around known interfaces instead of bespoke fittings.
About This Component
The Dual-Row Tube Clamp (Mixed Sizes) is supplied as a single-use molded part for IV infusion sets and tubing flow control. Its interface follows standard conventions so it mates predictably with compatible components, and it is produced in acetal (POM) by default, with other medical-grade resins available on request.
Like all Baixin Bio components, it can be customized for material, color, dimensions, packaging and assembly. For a precise specification — exact dimensions, tolerances, sterilization validation, packaging counts and minimum order quantity — request a drawing and samples through the inquiry form.
Key Advantages
Where dual-row tube clamp (mixed sizes) earns its place, it is for a handful of practical reasons:
- High-volume manufacturing with stable quality
- Compatibility with common sterilization methods
- Standardized interface that interoperates with compliant luer components
- Leak-resistant seal that holds under normal line pressure
- Single-use design that supports sterile, disposable workflows
- Medical-grade resin selected for fluid compatibility
None of these advantages matter in isolation; their value is cumulative. A part that seals well but drifts dimensionally, or one that is consistent but slow to supply, fails the assembler. The point is to get all of them at once, reliably, lot after lot.
Common Applications
The settings that rely on dual-row tube clamp (mixed sizes) include:
- Hemodialysis circuits
- Enteral feeding sets
- Laboratory fluid handling
- Irrigation sets
- Disposable diagnostic devices
What links these applications is risk. Each one moves fluid into or out of a patient or a sample, so a leak, a wrong connection or a contaminated surface has consequences. Standardized single-use components reduce that risk by making every junction predictable and by being discarded rather than reprocessed, which is the safer default for most modern disposable devices.
How to Specify and Choose
A good specification answers a short list of questions up front:
- Packaging format and order volume for the program
- The connection standard the mating part uses (luer slip, luer lock or a specific ISO 80369 series)
- The working pressure the junction must hold without leaking or separating
- The fluid and its chemical compatibility with the candidate resin
- The inner and outer diameters of the tubing the part bonds to
Getting these settled early means the first samples are usable and the program moves to volume faster. When a standard part does not fit, the same variables become the brief for an OEM or ODM tooling project.
Industry Standards
From a compliance standpoint, the component sits at the intersection of connector standards and material standards. The ISO 80369 family governs small-bore connection geometry to prevent misconnection, while biocompatibility documentation and a validated sterilization route — EO, gamma or autoclave — establish that the molded material is acceptable for its intended contact.
For acetal (POM) components, the practical sterilization options are EO; the choice is confirmed against the finished device and its validated process.
The reason the standards landscape moved toward ISO 80369 is patient safety: when every line used the same luer taper, it was physically possible to connect, say, an enteral line to an intravenous one. The newer series give different applications deliberately incompatible geometries so a dangerous misconnection cannot be made by accident. For a component maker, that means confirming which series an application requires before specifying a part.
This page is informational and does not replace device-specific regulatory or validation guidance. Confirm exact standards, biocompatibility and sterilization requirements for your product with your quality team and your supplier.
Frequently Asked Questions
Can I request samples?
Yes. Samples and drawings are welcome and recommended before committing to volume. Use the inquiry form to request them.
Is dual-row tube clamp (mixed sizes) available for OEM or ODM projects?
Yes. Baixin Bio manufactures to drawings and samples, customizing material, color, dimensions, packaging and assembly. Send your specification for a quote.
What materials are used?
Depending on the part, medical-grade PC, PP, PVC, ABS, PE or POM is used, selected for the connection method, fluid path and sterilization requirement.
How is it sterilized?
Components are compatible with validated single-use sterilization such as ethylene oxide, gamma irradiation or steam autoclave, depending on the resin. Confirm the method for your device.