What is Roberts Clamp (Small) used for?

Quick Answer

The Roberts Clamp (Small) (TS-003) is a medical plastic component used in IV infusion sets and tubing flow control. It provides a secure, single-use connection in the fluid path and is molded from acetal (POM). Baixin Bio supplies it in standard form and with OEM/ODM customization.

Definition

A roberts clamp (small) is one of the small standardized parts that make a medical fluid path work. Its job is to connect, seal or control flow between two segments of a line, and it is manufactured from device-qualified plastics for reliable single-use performance.

What separates a medical-grade part from a generic fitting is repeatability. Sealing surfaces are smooth and consistent, dimensions hold across the lot, and the resin is selected for fluid compatibility and sterilization.

It helps to picture where the part sits. A finished single-use device — an IV set, a transfer line, a dialysis circuit — is an assembly of molded plastic pieces joined into one fluid path. Each piece has a narrow job, and the value of standardization is that pieces from a catalog snap together predictably, so an assembler can design around known interfaces instead of bespoke fittings.

About This Component

The Roberts Clamp (Small) is supplied as a single-use molded part for IV infusion sets and tubing flow control. Its interface follows standard conventions so it mates predictably with compatible components, and it is produced in acetal (POM) by default, with other medical-grade resins available on request.

Like all Baixin Bio components, it can be customized for material, color, dimensions, packaging and assembly. For a precise specification — exact dimensions, tolerances, sterilization validation, packaging counts and minimum order quantity — request a drawing and samples through the inquiry form.

Key Advantages

The practical advantages of roberts clamp (small) cluster around safety, consistency and supply:

  • Dimensional consistency across production lots
  • Smooth fluid-contact surfaces for reliable connection
  • Available in multiple materials and colors
  • Supports OEM and ODM customization of dimensions and packaging
  • High-volume manufacturing with stable quality
  • Compatibility with common sterilization methods

None of these advantages matter in isolation; their value is cumulative. A part that seals well but drifts dimensionally, or one that is consistent but slow to supply, fails the assembler. The point is to get all of them at once, reliably, lot after lot.

Common Applications

You will find roberts clamp (small) across a range of single-use fluid-handling assemblies, including:

  • Laboratory fluid handling
  • Irrigation sets
  • Disposable diagnostic devices
  • Syringe and pump connections
  • IV infusion sets

What links these applications is risk. Each one moves fluid into or out of a patient or a sample, so a leak, a wrong connection or a contaminated surface has consequences. Standardized single-use components reduce that risk by making every junction predictable and by being discarded rather than reprocessed, which is the safer default for most modern disposable devices.

How to Specify and Choose

A good specification answers a short list of questions up front:

  • The working pressure the junction must hold without leaking or separating
  • The fluid and its chemical compatibility with the candidate resin
  • The inner and outer diameters of the tubing the part bonds to
  • The sterilization method the finished device will undergo
  • Whether the part is single-use or intended for limited reuse

With those answers in hand, a supplier can confirm a standard part or scope a custom one without back-and-forth. Sharing a drawing or a physical sample removes the remaining ambiguity.

Industry Standards

From a compliance standpoint, the component sits at the intersection of connector standards and material standards. The ISO 80369 family governs small-bore connection geometry to prevent misconnection, while biocompatibility documentation and a validated sterilization route — EO, gamma or autoclave — establish that the molded material is acceptable for its intended contact.

For acetal (POM) components, the practical sterilization options are EO; the choice is confirmed against the finished device and its validated process.

The reason the standards landscape moved toward ISO 80369 is patient safety: when every line used the same luer taper, it was physically possible to connect, say, an enteral line to an intravenous one. The newer series give different applications deliberately incompatible geometries so a dangerous misconnection cannot be made by accident. For a component maker, that means confirming which series an application requires before specifying a part.

This page is informational and does not replace device-specific regulatory or validation guidance. Confirm exact standards, biocompatibility and sterilization requirements for your product with your quality team and your supplier.

Frequently Asked Questions

Can I request samples?

Yes. Samples and drawings are welcome and recommended before committing to volume. Use the inquiry form to request them.

Is roberts clamp (small) available for OEM or ODM projects?

Yes. Baixin Bio manufactures to drawings and samples, customizing material, color, dimensions, packaging and assembly. Send your specification for a quote.

What materials are used?

Depending on the part, medical-grade PC, PP, PVC, ABS, PE or POM is used, selected for the connection method, fluid path and sterilization requirement.

How is it sterilized?

Components are compatible with validated single-use sterilization such as ethylene oxide, gamma irradiation or steam autoclave, depending on the resin. Confirm the method for your device.

Is it compatible with ISO 80369?

Luer interfaces follow small-bore connector conventions. Confirm exact ISO 80369 series compatibility for your application with Baixin Bio before specifying.

What order volumes are supported?

Baixin Bio supplies disposable device assemblers in production volumes, with consistent lot-to-lot quality and export-friendly communication.

Explore More

Need Medical Connectors or Components?

Baixin Bio manufactures luer connectors, valves, drip chambers, clamps, caps and tubing, with OEM and ODM customization. Send your drawings or samples for a quote.

Request a Quote